Renumbering

Overview

Renumbering allows you to create rules for any Fabrication (ITM) or Family (RFA) based element in the project. These rules define which elements are numbered, how the elements are numbered, and if the elements are tagged automatically.

IMPORTANT: make sure the Renumber Settings are properly set up before renumbering elements.

Using the Renumber feature

When using this feature, you have several options for how to apply the numbers to your selection.

Renumber
  • Renumber Elements - default grouping of elements based on user-defined rules.
  • Renumber Elements by Spool - runs the rule set against each spool in the selection, resetting the starting value with each spool
  • Renumber Elements by Service - runs the rule set against each spool in the selection, resetting the starting value with each Service Name
Options
  • Select Run to Specify Order - this option displays the selection in a temporary view and allows the user to pick the start and endpoint of the run to define the direction in which elements are renumbered.
  • Select Objects to Specify Order - this option displays the selection in a temporary view and allows the user to pick each element to define the renumbering order.

NOTE: If you have run this feature, but do not see any number tags in your model then check your Renumber Settings and make sure that the tag element option is selected for the rule you are using. Otherwise, you can use the number tag to place these tags after the elements have been numbered.

Relevant Articles

Renumber Settings


How did we do?


Powered by HelpDocs (opens in a new tab)

Powered by HelpDocs (opens in a new tab)